Chinese | English

Product center

  • ZDMS0.8 / 30S automatic tracking positioning jet fire extinguishing device

    ??:ZDMS0.8/30S ????30L/S@0.8Mpa Model: ZDMS0.8 / 30S flow pressure 30L/S@0.8Mpa

    Jet radius: 62 meters Protection radius: 55 meters

    Monitoring radius: 80 meters Water spray method: columnar / mist

    Installation height: 6 ~ 15 meters Horizontal turning angle: 0 ~ 360

    Tilt angle: -90 ~ + 30 Operating temperature range: -15 ~ + 105

    Working voltage: AC220V Working mode: on-site manual / remote manual / automatic

    Positioning time: ?55S Communication method: RS485 Power consumption: monitor 1W, scan 80W

    Detector method: Red UV composite interface Size: DN65 Flange installation method: Hoisting

    configuration list:

    Water cannon assembly SX-SP20S 1

    Solenoid valve SX-MV220V 1

    Field control box SX-ECU 1

    Signal decoder box SX-JM 1


    Surveillance camera (optional) SX-CAM 1

    Centralized control cabinet (optional) 1 SX-CC

  • ZDMS0.8 / 20S automatic tracking positioning jet fire extinguishing device

    ??:ZDMS0.8/20S ????20L/S@0.8Mpa Model: ZDMS0.8 / 20S flow pressure 20L/S@0.8Mpa

    Jet radius: 56 meters Protection radius: 50 meters

    Monitoring radius: 60 meters Water spray method: columnar / mist

    Installation height: 6 ~ 15 meters Horizontal turning angle: 0 ~ 360

    Tilt angle: -90 ~ + 30 Operating temperature range: -15 ~ + 105

    Working voltage: AC220V Working mode: on-site manual / remote manual / automatic

    Positioning time: ?55S Communication method: RS485 Power consumption: monitor 1W, scan 80W

    Detector Type: Red UV Composite Interface Size: DN65 Flange Installation: Hoisting

    configuration list:

    Water cannon assembly SX-SP20S 1

    Solenoid valve SX-MV220V 1

    Field control box SX-ECU 1

    Signal decoder box SX-JM 1


    Surveillance camera (optional) SX-CAM 1

    Centralized control cabinet (optional) 1 SX-CC

  • ZDMS0.6 / 10S automatic tracking positioning jet fire extinguishing device

    ??:ZDMS0.6/10S ????10L/S@0.6Mpa Model: ZDMS0.6 / 10S flow pressure 10L/S@0.6Mpa

    Jet radius: ?39 meters Protection radius: ?35 meters

    Monitoring radius: ?40 meters Water spray method: columnar

    Installation height: 6 ~ 15 meters Horizontal turning angle: ?330

    Tilt angle: -90 ~ + 30

    Working voltage: AC220V Working mode: on-site manual / remote manual / automatic

    Positioning time: ?30S Communication method: RS485 Power consumption: monitor 1W, scan 50W

    Detector Type: Red UV Composite Interface Size: DN50 Flange

    Installation method: Hoisting

    configuration list:

    Water cannon assembly SX-SP5S 1

    Solenoid valve SX-MV220V 1

    On-site control box SX-ECU

    Signal decoder SX-JM 1


    Surveillance camera (optional) SX-CAM 1

    Centralized control cabinet (optional) 1 SX-CC

  • ZDMS0.6 / 5S automatic tracking positioning jet fire extinguishing device

    Model: ZDMS0.6 / 5S flow pressure 5L/S@0.6Mpa

    Jet radius: 28 meters Protection radius: 25 meters

    Monitoring radius: 30 meters

    Installation height: 6 ~ 15 meters Horizontal turning angle: ?330

    Tilt angle: -90 ~ + 30 Operating temperature range: -15 ~ + 105

    Working voltage: AC220V Working mode: on-site manual / remote manual / automatic

    Positioning time: 30S Communication method: RS485 Power consumption: monitor 1W, scan 50W

    Detector Type: Red UV Composite Interface Size: DN50 Flange

    Installation method: Hoisting

    configuration list:

    Water cannon assembly SX-SP5S 1

    Solenoid valve SX-MV220V 1

    On-site control box SX-ECU

    Signal decoder SX-JM 1


    Surveillance camera (optional) SX-CAM 1

    Centralized control cabinet (optional) 1 SX-CC

  • ZDMP0.2 / 5S automatic tracking positioning jet fire extinguishing device

    Model: ZDMS0.2 / 5S flow pressure 5L/S@0.2Mpa

    Jet radius: ? 6.7 meters Protection radius: ? 6 meters

    Monitoring radius: ?9 meters Water spray method: columnar

    Installation height: 6 ~ 15 meters Horizontal rotation angle: ?360

    Tilt angle: -90 ~ + 30 Operating temperature range: -15 ~ + 105

    Working voltage: AC220V Working mode: on-site manual / remote manual / automatic

    Positioning time: ?30S Communication method: RS485 Power consumption: monitor 1W, scan 50W

    Detector Type: Red UV Composite Interface Size: DN50 Flange

    Installation: Hoisting

    configuration list:

    Water cannon assembly SX-SP5S 1

    Solenoid valve SX-MV220V 1

    On-site control box SX-ECU

    Signal decoder SX-JM 1


    Surveillance camera (optional) SX-CAM 1

    Centralized control cabinet (optional) 1 SX-CC